the battery in real time.If the battery temperature is too high, we will reduce the charging
current intelligently,ensure safety.To increase temperature sensitivity, a milky white
thermal conductive adhesive is added below the circular metal. If a small amount of
colloid seeps out, please remove it with a cloth.
1. Temperature is higher than 65
℃
. If the charging current is higher than 1500
mA(excluding 1500 mA), it will be reduced to 2 level, for example your current charge
current is 3000mA, it will be automatically charged at 2000mA.
2. The temperature of the slot is more than 70
℃
. If charge current is more than 500 mA
(excluding 500 mA), the charging current will be forced to drop to 500 mA.
Battery charging current level:
250mA, 500mA, 1000mA, 1500mA, 2000mA, 2500mA, 3000mA
3.5 Re-change MODE or CURRENT
If the battery is charging or discharging, other modes can be changed by pressing the
MODE button for 2 seconds, and the current can be changed immediately after changing
the mode, but the data on the previous display will disappear. Please be careful.
When the charger works normally, if it is in automatic mode, press and hold the current
button for more than 2 seconds to forcibly change the current. When grease or other
factors affect the measurement of battery internal resistance, we can forcibly select the
appropriate charging current of the battery. In manual mode, press and hold the current
button, and the current will not change.
3.6 Extending the Service Life of Charger
This is an intelligent multi-function charger.
In order to obtain a longer service life, please keep operate in dry environment in door,
and have enough space to emit heat. In order to prolong the service life, please try not to
discharge/charge four slots at full load for a long time. Because full-load operation will