EasyManua.ls Logo

Varec 6700 - Page 41

Varec 6700
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Varec, Inc. 33
routed through the float guide holes and rotate the guide cable retainers to lock the guide
cable in place. Tighten the nuts and set the float on the tank bottom or bottom anchor.
16. Perform steps 27 - 32 under Cone Roof Tank Installation.
17. Tape the gaugeboard indicator to the gaugeboard at a level indication of 2.00 inches [50.8
mm] plus the height of the bottom anchor. Adjust the cable tension until the float barely
lifts from its resting place. Crimp the cable connector and remove the tape.
Note As the float is four inches [101.6 mm] high and its waterline is at its equator, it can-
not register the last two inches [50.8 mm] plus any bottom anchor height of liquid in the
tank.
18. Complete the installation by performing steps 34 - 36 under Cone Roof Tank Installation.

Table of Contents