8
The machine is turned on, but the engine works intermittently or stops:
• Examine the fuel tank assembly to check for any leakages.
After pressing the start button, cover the tank and connections with soap to check for leaks. If bubbles are observed,
the gasket needs replacing on the fuel tank cap or the tank itself.
• Clean the resonator.
Remove carbon deposits in the resonator with the wire brush provided. Use and forward and backward motion.
The machine doesn’t fog or doesn’t fog enough:
Check that the chemical supply valve is opened. This is done by turning it anticlockwise. Make sure that the
directional/close valve is set to the open position.
• Unscrew the main chemical inlet nozzle from the resonator and clean it using compressed air to remove any
blockages.
• Check there is no leaks in the chemical tank. Blow compressed air backwards though the chemical tube from the
inlet nozzle to see if any bubbles appear. Replace leaking parts if necessary.