TABLE 1 - INVERTER POWER SWITCH TURNED ON CON’T
TROUBLE/INDICATION POSSIBLE CAUSE SUGGESTED REMEDY
Motorized power tool Purely inductive load Make the load not purely
does not operate at inductive. Operate an
correct speed incandescent lamp at
same time as motor
Television/Radio Snow in picture, buzz Keep inverter and
interference in speaker antenna distant from
each other. Use shielded
antenna cable. Connect
antenna to amplifier
8. SPECIFICATIONS
Maximum Continuous Power................................. 400 watts
Surge Capacity (Peak Power) ................................. 800 watts
Maximum Efficiency Approx. ......................................... 90%
No Load Current Draw ................................................ 0.3A
Low Voltage Shutdown Activation ..................... 10.0 volts DC
Low Voltage Alarm Activation .......................... 10.6 volts DC
Wave Form........................................... Modified Sine Wave
No. of AC Receptacles....................................................Two
Fuses.............................................Two 25 Amp (spade-type)
Weight ...................................................... 2.42 lbs. (I.1 kg)
Length .................................................. 6-3/8 in. (16.2 cm)
Width .................................................. 6-1/8 in. (15.6 cm)
Height .................................................... 2-1/8 iri. (5.4 cm)