Installation and Startup Guide
This document covers the installation of MT6103iP Series HMI, for the detailed specifications and operation,
please refer to Brochure and EasyBuilder Pro User Manual.
Install Environment:
NEMA Rating
MT6103iP Series HMI is NEMA 4 rated (Indoor Only).
Electrical
Environment
MT6103iP Series has been tested to conform to European CE requirements. This
means that the circuitry is designed to resist the effects of electrical noise. This
does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the displays are installed correctly and that the operating
limits are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2) Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4) This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5) Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in
Pollution Degree 2 Environment.
Unpacking the Unit
Unpack and check the delivery. If damage is found,
notify the supplier.
Installation Instructions
Secure the operator panel in position, using all the fastening holes and the provided brackets
and screws. Screw Torque: 2.6 ~ 3.9 lbf.in. (For reaching waterproof effect and preventing the panel from
being deformed.)
Type
A(mm)
B(mm)
MT6103iP
260
202
Power Connections
System Settings
When HMI is powered up and displays image,
click the system setting button.
(Default System Password: 111111)
MT6103iP series
Installation Instruction
1
2
NOTE:
Place the operator panel on a stable
surface during installation. Dropping it or
letting it fall may cause damage.
5
Go to the Security tab, the default
password is 111111, click the buttons to
set your own passwords.
4
NOTE:
1. Connect positive DC line to the ‘+’ terminal
and the DC ground to the- terminal.
2. Please do not connect HMI with PLC and PC
simultaneously to prevent potential difference
from destroying USB ports of HMI and PC.
(A)
(B)
Cutout
(1)
(2)
(5)
(4)
(3)
(1) Installation Instruction, 2-sided A4 *1
(2) Human Machine Interface *1
(3) Power Connector *1
(4) Brackets & Screws *1 pack
(5) Fuse 1.25A/250V 5*20mm *1
Question and Answer IconNeed help?

Do you have a question about the veinview MT6103iP series and is the answer not in the manual?

veinview MT6103iP series Specifications

General IconGeneral
Brandveinview
ModelMT6103iP series
CategoryTouch Panel
LanguageEnglish

Summary

Installation and Startup Guide

Install Environment

Covers NEMA rating, electrical noise resistance, and environmental considerations for installation.

Unpacking the Unit

Lists all components included in the package: manual, HMI unit, power connector, brackets, and fuse.

Installation Instructions

Secure the Operator Panel

Instructions for mounting the panel using provided brackets and screws with specified torque.

Power Connections

Connect Power Supply

Details on connecting 24V DC power and avoiding simultaneous PLC/PC connections via USB.

System Settings

Access System Settings

Guide to access system settings via touchscreen button and default password.

EasyBuilder Pro Software Settings

Download Project to HMI

Steps to launch EasyBuilder Pro, select project, and download via USB.

Communication Connections

COM Port Configurations

Details on COM1 (RS232), COM2 (RS485 2W/4W), and COM3 (RS485 2W) pin assignments.

Jumper Settings

Configure Jumper Settings

Table and explanation for jumper settings like Touch Screen Calibration and Normal mode.

General Cautions

Safety Precautions

Covers electrical standards, voltage, fusing, high voltage, emergency stop, supply voltage, and wire routing.

System Safety Considerations

Programmable Control System Safety

Discusses system designer responsibilities, electrical interference, and precautions for programmable control systems.