F3.1 PARITY
Select the type of parity desired from the three options: No parity(nP), Parity
Even(PE), or Parity Odd(Po.)
Options: nP, PE, Po
F3.2 PARITY, BITS per CHARACTER, and STOP BITS
Select the needed parity, number of bits per character, and the number of
STOP bits from the options below. The leftmost character is the parity (n
or P), the middle character is the number of bits (7 or 8) and the rightmost
character is the number of stop bits (1 or 2). If parity is selected, the type
of parity, even or odd, used is via the F3.1 PARITY selection above. An
nP selection in F3.1 above will override the P selection in this section.
Options: n7.1, n7.2, P7.1, P7.2, n8.1, n8.2, P8.1, P8.2
F3.3 DELAY AFTER CARRIAGE RETURN
The amount of delay after a carriage return or line feed is transmitted, in
seconds.
Options: 0, 0.1, 0.2, 0.5, 0.75, 1.0, 1.5
F3.4 NEGATIVE PRINT ENABLE
d Disable the printing of negative weights.
E Enable printing of negative weights (Non HB44.)
F3.5 CHECKSUM TRANSMIT ENABLE
d No checksum transmitted.
E Checksum is transmitted, prior to CR-LF, as the 2s complement of previously
sent characters.
F3.6 CTS ENABLE
d Ignore CTS input line.
E Use the CTS input line to control character transmission. If CTS is false,
do not transmit.