CU2200_v5 VELLEMAN 10
ZZZZ Selection of the alarm phone dial and alarm SMS
0 means no alarm report
1 means SMS only
2 means phone dial only
3 means SMS first, then phone dial
ZZZZ
4
th
phone number
3
rd
phone number
2
nd
phone number
1
st
phone number
NNN Relay output control
0 means no relay output control
1 means relay output triggered by alarm
NNN
3
rd
relay output (not available)
2
nd
relay output (not available)
1
st
relay output
Arm/Disarm Setup
Command: PWD:XXXX,ARM%
XXXX Password
Example:
PWD:1234,ARM%
Password 1234
Unit is armed and in alert status
Command: PWD:XXXX,DISARM%
XXXX Password
Example:
PWD:1234,DISARM%
Password 1234
Unit is disarmed and no alarm is reported
c. System Information Report
Default Setting
Command: PWD:1234,PARAMETER1%
ST:000;T:2006/10/01/01:01;H:1;F1:,00;F2;,00;C1:,1;C2:,1;C3:,1;C4:,1;XH:20#;
Command: PWD:1234,PARAMETER2%
ST:000;VL:7.00,O:00,0000,000;A1M:5.000,1.000,0,5.000,0.500,O:00,0000,000;A2M:5.000,1.000,0,5.000,0.00
0,O:00,0000,000;K1:1,O:00,0000,000,#;
Command: PWD:1234,PARAMETER3%