ST:000;K2:1,O:00,000,0;K3:1,O:00,000,0;K4:1,O:00,000,0;K5:1,O:00,000,0;K6:1,O:00,000,0;K7:1,O:00,000,0;
K8:1,O:00,000,0;
System Parameters RESET
Command: PWD:XXXX,PARAMETER&%
[SMS message received]
Parameter initialize success!
Return Message
Command succeeds
SMS message: Function Code & Setting Parameters Set in the command
Command fails
SMS message: SMS Format is error!
System Parameters Report
Command: PWD:XXXX,PARAMETER1%
[SMS message received]
ST:XXX;T:2006/10/08/08:00;H:X;F1:XXXXXXXXXXX,YY;F2:XXXXXXXXXXX,YY;C1XXXXXXXXXXX,Y;C2:XX
XXXXXXXXXX,Y;C3:XXXXXXXXXXXX,Y;C4XXXXXXXXXXX,Y;XH:XX#
ST: Unit serial number
T: Date/time
H:X Arm/disarm
F1 1
st
control centre number
XXXXXXXXXX Control centre number
YY Automatic health report schedule
C1 1
st
alarm report phone number
XXXXXXXXXX Alarm report phone number
Y Alarm report enabled/disabled
XH:XX GSM network signal strength (1 ~ 31)
Command: PWD:XXXX,PARAMETER2%
About the alarm channel
[SMS message received]
ST:XXX;VL:XXXXX,O:AX,BBBB,CCC:A1M:XXXXX,XXXXX,R,WWWWW,WWWWW,O:AX,BBBB,CCC;A2M:X
XXXX,XXXXX,R,WWWWW,WWWWW,O:AX,BBBB,CCC;K1:N,O:AX,BBBB,CCC;#
VL Min. operating voltage (7VDC by default), alarm will be triggered if voltage drops below this level
A Alarm report to control centre 1
0 means no report
1 means report
X Alarm report to control centre 2
0 means no report
1 means report
BBBB Report status for 4 phone numbers
0 means no report
1 means SMS but no phone dial
2 means phone dial but no SMS
3 means SMS first and then phone dial