Example 2:
PWD:1234,ALMLEVEL1:1,11,1230,100#%
Password 1234
Alarm channel 2 Once the input is closed, the alarm will be triggered
Control centre 1 and 2 will be reported by SMS
Phone number 1
Phone number 2
Phone number 3
Phone number 4
Relay output 1
Relay output 2
Relay output 3
SMS message
Phone dial
SMS message, then phone dial
No report
Triggered
No control (not available)
No control (not available)
SMS Alarm Message Setup
Alarm channel 1 ~ 8
Command: PWD:XXXX,ALMYTEXT:□□□□□□□□□□□□#%
XXXX Password
Y Alarm channel number (1 ~ 8)
□□□□□□□□ SMS message (max. 100 characters – no space allowed)
Example:
PWD:1234,ALM4TEXT:DoorContact1Open#%
Password 1234
Alarm channel 4 is triggered, SMS message Door Contact 1 Open is sent to
the pre-defined phone numbers.
SMS Message Contents
Command 8 is used to program the alarm message contents. The CU2200 will reply to the mobile phone with
the programmed message for that alarm channel.
Command: PWD:XXXX,READYTEXT%
XXXX Password
Y Alarm channel number (1 ~ 8)
Commanding the CU2200 to Send SMS Message
This command is used to make the CU2200 to send the SMS message for testing purposes.
Command: PWD:XXXX,SENDMSA:B%
XXXX Password
A Phone number (1 ~ 4)
B SMS message selection
0: schedule health check content
1~8: alarm channel SMS message content
9: manual input message content