DEM501
V. 01 07/05/2015 6 ©Velleman nv
dew point temperature
accuracy
-20° C to 70° C
(-4° F to 158° F)
+/- 1.0° C (1.8° F)
response time
1 sec.
sample rate
1x / sec.
overload indication
"OL"
resolution
0.1 % RH, 0.1° C, 0.1° F
operating conditions
-20° C to 70° C (14° F to 158° F);
< 80 % RH non-condensing
storage conditions
-20° C to 70° C (14° F to 158° F);
< 80 % RH non-condensing
auto power-off
device shuts down automatically if no key is
pressed for ± 15 min.
battery
1x 9 V 6F22 (incl.)
dimensions
192 x 62 x 33 mm
weight (with battery)
± 151 g
Use this device with original accessories only. Velleman nv cannot
be held responsible in the event of damage or injury resulting from
(incorrect) use of this device. For more info concerning this product
and the latest version of this manual, please visit our website
www.velleman.eu. The information in this manual is subject to
change without prior notice.