Do you have a question about the Velleman DCM266 and is the answer not in the manual?
Continuity test | Yes |
---|---|
Diode test | Yes |
Transistor test | Yes |
Square wave output | Yes |
Power Supply | 9V battery |
AC voltage | 200V/600V |
Battery test | 1.5V, 9V |
Measurement Range | Varies by function |
Resolution | Varies by function |
DC voltage | 200mV/2V/20V/200V/600V |
DC current | 200µA/2mA/20mA/200mA/10A |
Resistance | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ |
User must observe all normal safety rules concerning protection against current dangers and meter misuse. Ensure compliance with safety standards.
Instructions for safe operation, including not exceeding limits, avoiding touching unused terminals, selecting ranges, and precautions for specific circuits.
Explains symbols like important safety information, dangerous voltage, earth ground, and double insulation.
Guidelines for meter maintenance, including disconnecting power before opening, checking for faults, and cleaning methods.
Describes the rotary switch for selecting measurement functions and ranges, and that the meter is off when set to OFF.
Explains how to use the trigger to open and close the transformer jaws for AC current measurement.
Mentions a push switch for data hold function available on ACA, ACV, and DCV ranges.
Details the three input jacks and connection procedures for test leads, including the EXT jack for insulation testers.
Steps for measuring AC current using the transformer jaws, including handling overrange indication.
Procedure for performing insulation tests using the optional 500V insulation tester unit, including connections and settings.
Instructions for measuring DCV or ACV, connecting leads, and interpreting overrange indications.
Steps for measuring resistance, including lead connection, range selection, and safety notes for in-circuit measurements.
Procedure for continuity testing, including lead connection, range selection, and expected buzzer sound.
General specifications including display type, measuring system, voltage limits, operating/storage conditions, power, accessories, and dimensions.
Detailed specifications for AC current measurement, including range, resolution, accuracy, frequency range, response, and overload protection.
Specifications for insulation testing with the optional unit, detailing ranges, resolution, and accuracy for different resistance levels.
Specifications for AC voltage measurement, including range, resolution, accuracy, input impedance, overload protection, and frequency range.
Specifications for DC voltage measurement, including range, resolution, accuracy, input impedance, and overload protection.
Specifications for resistance measurement, including range, resolution, accuracy, overload protection, and open circuit voltage.
Lists the accessories included with the meter: test leads, battery, and operating manual.
Instructions on how to replace the battery when the "BAT" indicator appears, with a safety warning.