7.3 Setting the Measurement Benchmark
Press the units button to switch between the end (default), the front
and the extended benchmarks. Use the extended benchmark with the
deployed belt buckle.
7.4 Single or Continuous Measurement
Single Measurement
1. Press the distance button to switch on the laser.
2. Aim the laser towards the object to be measured.
3. Press the distance button to measure the distance. The value appears
on the LCD display.
Continuous Measurement
1. Hold the distance button pressed to enter the continuous measuring
mode.
2. Aim the laser towards the object to be measured.
3. Press the distance button again to exit the continuous measuring
mode.
7.5 Area Measurement
1. Press the area/volume button to enter the area-measuring mode.
2. Press the distance button and measure the length.
3. Press the distance button and measure the width.
4. The meter automatically calculates the area. The value appears on the
LCD display.
5. Press the area/volume button to exit the mode.
7.6 Volume Measurement
1. Press the area/volume button twice to enter the volume-measuring
mode.
2. Press the distance button and measure the length.
3. Press the distance button and measure the width.