DVM890 GB 7
4.5. AC Current
Range Resolution Accuracy
20mA 10µA
± 1.2% of rdg ± 3 digits
200mA 100µA
± 2.0% of rdg ± 3 digits
20A 10mA
± 3.0% of rdg ± 7 digits
Overload Protection : F 0.2A fuse (20A-range is not protected by a fuse)
Frequency Range : 40 to 400Hz
Max. Input Current : 20A, 15 sec.
4.6. Resistance
Range Resolution Accuracy
200 0.1 ± 0.8% of rdg ± 3 digits
2k 1
20k 10
200k 100
2M 1k
± 0.8% of rdg ± 1 digit
20M 10k ± 1% of rdg ± 2 digits
200M 100k ± 5% of rdg ± 10 digits
4.7. Capacitance
Range Resolution Accuracy
2000pF 1pF
20nF 10pF
200nF 100pF
F 1nF
20µF 10nF
± 2.5% of rdg ± 5 digits
4.8. Temperature
Range Temperature Range Resolution Accuracy
- 50°C to 400°C
± 0.75% of rdg ± 3°C
400°C to 1000°C
± 1.5% of rdg ± 15°C
T
 0°C to 40°C
1°C
± 2°C
Using a K-type thermocouple probe  Using the built-in temperature sensor
4.9. Frequency
Range Resolution Accuracy
20kHz 10Hz
± 1% of rdg ± 1 digit
Overload Protection : AC 220Vrms