EasyManua.ls Logo

Velleman DVM901 - 9.3 DC CURRENT; 9.4 AC CURRENT

Velleman DVM901
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DVM901
V. 02 29/01/2020 10 ©Velleman nv
9.3 DC CURRENT
Do not measure circuits that may contain voltages
> 700 VDC or > 700 VAC
range
resolution
accuracy
400 µA
0.01 µA
± (1.0 % + 2)
4000 µA
0.1 µA
40 mA
1 µA
400 mA
10 µA
4 A
100 µA
± (2.0 % + 3)
15 A
1 mA
Overload protection: F0.5 A/700 V fuse, F15 A/700 V fuse
Continuous testing maximum steady-state current of 1 A
9.4 AC CURRENT
Do not measure circuits that may contain voltages
> 700 VDC or > 700 VAC
range
resolution
accuracy
400 µA
0.01 µA
± (1.2 % + 10)
4000 µA
0.1 µA
40 mA
1 µA
400 mA
10 µA
4 A
100 µA
± (1.5 % + 10)
15 A
1 mA
AC true RMS
Frequency range: 40 Hz-1 kHz
Overload protection: F0.5 A/700 V fuse, F15 A/700 V fuse
Continuous testing maximum steady-state current of 1 A

Table of Contents