Do you have a question about the Velux FCM and is the answer not in the manual?
Application | Residential and Commercial |
---|---|
Frame Material | Aluminum |
Curb Type | Site-built curb |
Operation | Non-operable |
Size Range | Various sizes available |
Installation | Requires professional installation |
Roof pitch range (0-60°) and special notes for low pitches (<15°).
Details ECL (10-60°) and ECW (14-60°) flashing types for roof pitch compatibility.
Disclaimers regarding installer responsibility, laws, codes, and safety requirements.
Information on glass types (laminated/tempered) and breakage risks.
Maintain specified clearances from critical roof areas like valleys and ridges.
Specifications for curb lumber thickness (1/2") and minimum height (3.5").
Chart detailing skylight sizes and corresponding exterior curb and flashing dimensions.
Special framing requirements for cyclonic or high wind area installations.
Instructions for steps 2 (remove batten) and 3 (install framing members).
Illustration of framing members and support battens for light shaft integration.
Instructions for wrapping the skylight curb with VELUX roofing underlayment ZOZ 216.
Waterproofing measures for low roof pitches (<15°) and potential snow accumulation.
Detailed steps for creating water-shedding laps with underlayment on the curb.
Procedure for wrapping the top curb frame with underlayment.
Interweaving felt with underlayment for proper drainage in new and retrofit applications.
Selection guide for ECL (thin roofing) and ECW (profiled roofing) flashing types.
Considerations for using custom-made flashing options A, B, or C.
Procedure for centering and securing the skylight using provided screws.