Page #1 background imageLoading...
Page #1 background image
100 Series
Thermostatic and Rain Controller
Installation Guide
Tel: +44(0)1202 744958 Fax: +44(0)1202 733026
Email: info@vent.co.uk Web: www.vent.co.uk
Unit 16c & 16f, Chalwyn Industrial Estate, Poole, Dorset BH12 4PE
To enter ‘advanced’ setup set your unit to “AUTO
mode then press and hold the AUTO/MAN plus
SET +/- buttons simultaneously for 5 seconds.
Your screen should now read..
ADV
SETUP
After a moment the screen will change to display
To Advance
Press SET +/-
Using SET+/- is how you scroll through the
available options and saves each stage of any
alteration.
Now press “SET +/-”. The screen will read..
To + a value
Press Open
The Open button is used to increase any value.
Press “SET +/-” again. The screen will read..
To – a value
Press Close
The Close button is used to decrease any value.
Press “SET +/-” again. The display will read..
Proceed to
ADV Setup
Now you can proceed to the advanced setup
options.
Press “SET +/-” again. The display will read..
Room Temp
is now XXc
‘XX’ being the current temperature in your room.
By using Open(+) and Close(-) you can calibrate
the display temperature.
Press “SET +/-” again. The display will read
Full open
Cycle 013sec
013sec is the amount of time for the motor to
operate and fully open - in most cases this default
setting is adequate. You can of course, alter this
setting for your actuator by pressing the Open(+)
and Close(-) buttons.
Press “SET +/-” again. The display will read..
Opening
Temp =22c
This relates to the temperature that the room must
reach before the actuator will operate.
You can alter this setting by pressing the Open(+)
and Close(-) buttons.
Press “SET +/-” again. The display will read..
Closing
Temp =18c
This relates to the temperature that the room must
fall to before the actuator will operate.
You can alter this setting by pressing the Open(+)
and Close(-) buttons.
Press “SET +/-” again. The display will read..
AUTO LOCK
MODE OFF
Using autolock is a security feature that prevents
the unit from being used without entering a
passcode rst. You can turn this on or off by
pressing the Open(+) and Close(-) buttons.
Press “SET +/-” again will take you back to
AUTO MODE
The unlock sequence is:
Button 2
[ AUTO/MAN ]
Button 1
[ OPEN ]
Button 3
[ SET +/- ]
Button 4
[ CLOSE ]
100 Series Advanced Operations Guide
The default settings of our 100 series controller are suited to most user applications. However, if
you need to make advanced alterations such as; Thermostat, Actuator and Lock Calibration, then
please use the following guide.
fv10/100t/22092010
Question and Answer IconNeed help?

Do you have a question about the Vent 100 Series and is the answer not in the manual?

Vent 100 Series Specifications

General IconGeneral
DisplayLCD
Programmability7-day programming
Wi-Fi ConnectivityYes
Smart FeaturesRemote control via app, Voice control
CompatibilityHVAC systems

Summary

100 Series Advanced Operations Guide

Entering Advanced Setup

Instructions to enter advanced setup mode by pressing AUTO/MAN and SET+/- for 5 seconds.

Navigating Setup Options

Using SET+/- to scroll, Open(+) to increase, and Close(-) to decrease values in setup menus.

Configuring Actuator Cycle Time

Adjusting the default 013sec motor operation time for full opening or closing.

Setting Temperature Thresholds

Defining room temperatures for actuator operation (opening and closing).

Autolock Security Feature

Explanation of the security feature that prevents unit use without a passcode.

Calibrating Display Temperature

Using Open(+) and Close(-) buttons to calibrate the displayed room temperature.

Unit Unlock Sequence

The specific button sequence required to unlock the controller after autolock is enabled.

100 Series Installation Guide

Installation and Wiring Overview

Diagrams and steps for physical installation, connecting actuator, rain, and temp sensors.

Frequently Asked Questions

Answers to common user queries regarding rain sensor responsiveness, lock/unlock, and display issues.

Adjusting User Settings

Setting preset opening/closing temperatures and performing manual window operations.