TITLE SECTION
711105
IMPORTANT
ADEQUATE WIRING IMPERATIVE FOR PROPER OPERATION
1. PROPER GROUND PATH - SEE DWG 15660
2. CURRENT DRAW IS SEVERAL HUNDRED AMPERES -
ADEQUATE WIRE SIZE AND BATTERY CAPACITY IS ABSOLUTELY
ESSENTIAL (SEE CHART BELOW.)
* INCLUDES GROUND CABLE
** CCA=COLD CRANKING AMPS AT 0' F.
THE CCA RATING IS A MEASURE OF THE ABILITY OF THE BATTERY TO DELIVER A
HIGH CURRENT FOR A SHORT PERIOD OF TIME.
*** RC=RESERVE CAPACITY IN MINUTES AT 25 AMPS AND 80' F.
THE RC RATING IS A MEASURE OF THE
PERIOD OF TIME THE BATTERY CAN SUPPLY A GIVEN CURRENT WITHOUT RECHARGING.
MINIMUM WIRE GAUGE AND BATTERY SIZE
MODEL TOTAL LENGTH OF CABLE (FT)* 12 VOLT BATTERY REQUIREMENTS
0-20 21-25 26-30 31-40 41-50 51-60 61-70 71-80 CCA (A)** RC (MIN)***
CE6K
CT2000
CT2003/4/5 #4 #4 #2 #2 #1 #0 #0 #00 350 100
DT7K
ET5500MPB
ET5500R
ET6KMPB # 2 # 2 # 1 # 0 # 0 0 NOT RECOMMENDED 4 5 0 1 0 0
ET6KR
ET8K
ET10K
ET12K
ET8KX
ET10KX #2 #2 #1 #0 #00 NOT RECOMMENDED 5 5 0 1 5 0
ET12KX
ET25K SEE DRAWING I24600 FOR CABLE AND BATTERY REQUIREMENTS
ET25KX
CABLE & BATTERY 8-2-06S C200
CE, CT, DT, & ET 8-10-00R
DATE
SUPERCEDES
CINCINNATI, OHIO