Astro function / Run time correction Special functions
Below the switching sequence is presented in the course of an entire year under con-
sideration of summer/winter time, at an up time preset at 6:30 and a down time preset
at 19:30. These times relate to 10° of eastern longitude and 50° of northern latitude
which corresponds to the geographical location of the city of Würzburg. Setting DIP
switch 6 to “ON” will delay the down time of the roller shutter by 30 minutes.
Run time
correction:
- 49 -
DIP 6 Correction
OFF no delay
ON down command 30 minutes delayed
G
Special functions Astro function – Germany
Y12345C
= Manufacturer’s default setting:
Schleswig-Holstein,
Northern Lower-Saxony
- 50 -
DIP 2 DIP 3 DIP 4 DIP 5 Area
OFF OFF OFF OFF Schleswig-Holstein, Northern Lower-Saxony
OFF OFF OFF ON Mecklenburg-Vorpommern
OFF OFF ON OFF
North-Rhine Westphalia, Southern Lower-Saxony
OFF OFF ON ON Brandenburg, Saxony-Anhalt
OFF ON OFF OFF Rhineland-Palatinate, Saarland, Hesse
OFF ON OFF ON Saxony, Thuringia
OFF ON ON OFF Baden-Württemberg
OFF ON ON ON Bavaria