Model | MTS 6000A V2 |
---|---|
Weight | 3.5 kg |
Battery Life | Up to 8 hours |
Display Type | Color LCD |
Display | Touchscreen |
Ports | USB |
Protocols Supported | Ethernet |
Measurement Capabilities | OTDR, Power Meter, Light Source |
Operating Temperature | -10°C to +50°C |
Storage Temperature | -20°C to +60°C |
Power Supply | AC/DC, Battery |
Battery | Lithium ion |
Wavelength Range | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm |
Light Source Wavelengths | 1310 nm, 1490 nm, 1550 nm, 1625 nm |
Explains how to select and activate the OTDR function, including Smart Test and Expert OTDR modes.
Covers detailed configuration of reflectometry tests, including parameters for Smart Test and Expert OTDR modes.
Provides instructions on how to perform OTDR acquisitions in different modes like Real Time, Smart Test, and Expert OTDR.
Details advanced features available in Expert OTDR mode, such as cursors, zoom, and trace manipulation.
Guides users on selecting and configuring the Reduced Dead Zone (RDZ) function for multimode fiber analysis.
Details the steps for performing a measurement using the RDZ function, including acquisition and connection status.
Covers the activation and configuration of the power meter function, including measurement and alarm parameters.
Details the OEO configuration menu and parameters for setting up bi-directional measurements.
Outlines the step-by-step procedure for executing automatic bi-directional OTDR measurements.
Details how to configure the unit parameters for FiberComplete measurements.
Describes the procedures for performing various tests using FiberComplete.
Guides users through activating the PMD function and performing self-calibration for accurate measurements.
Details the procedure for performing PMD measurements using specific test modules and sources.
Guides users on activating and configuring the I-PMD function, including acquisition parameters and mode selection.
Details the steps for performing an in-band PMD-OSNR measurement using an I-PMD module.
Provides instructions for configuring the High Resolution OSA instrument and its parameters.
Explains various acquisition parameters for OSA measurements, including sweep, range, and mode settings.
Details the process of activating the Attenuation Profile (AP) function and performing self-calibration.
Provides step-by-step instructions for conducting Attenuation Profile measurements.
Guides users on activating the Chromatic Dispersion (CD) function and performing self-calibration.
Details the configuration of Chromatic Dispersion tests, including approximation formulas and parameters.
Provides instructions for performing CD measurements, including connections and setup.
Guides users through the process of activating the BBS function, including password entry.
Details how to configure the MTAU function, including selecting input channels.
Details how to perform fiber characterization tests manually.