Unitronics
1
Vision™PLC+HMI
User Guide
V700-T20BJ
V700-S-T20BJ
General Description
V700 OPLCs are programmable logic controller that comprise a built-in operating panel containing a 7” Color Touchscreen
You can find additional information, such as wiring diagrams, in the product’s installation guide located in the Technical Library at
www.unitronics.com
I/O Options
Snap-in I/O Modules / I/O Expansion Modules
Screen
7" Color Touch
Keypad or Function Keys
None
Programming Com Port, Built-in
RS232/485
Yes
Ethernet
Yes
USB device,
mini-B
Yes
Com Ports, separate order, installed
by user
The user may install one or both of the following ports:
CANbus port (V100-17-CAN)
RS232/RS485 port (V100-17-RS4/V100-17-RS4X)
* V700 comprises both RS232/485 and USB ports; note that only one channel may be used at a time.
Standard Kit Contents
Controller
Terminal Block
Battery
Mounting Brackets
Rubber Seal
Alert Symbols and General Restrictions
When any of the following symbols appear, read the associated information carefully.
Symbol
Meaning
Description
Danger
The identified danger causes physical and property damage.
Warning
The identified danger could cause physical and property damage.
Caution
Caution
Use caution.
Before using this product, the user must read and understand this document.
All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for
actual use of this product based on these examples.
Please dispose of this product according to local and national standards and regulations.
Only qualified service personnel should open this device or carry out repairs.
Failure to comply with appropriate safety guidelines can cause severe injury or property damage.
Do not attempt to use this device with parameters that exceed permissible levels.
To avoid damaging the system, do not connect/disconnect the device when power is on.
Environmental Considerations
Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,
moisture or rain, excessive heat, regular impact shocks or excessive vibration, in
accordance with the standards given in the product’s technical specification sheet.
Do not place in water or let water leak onto the unit.
Do not allow debris to fall inside the unit during installation.
Ventilation: 10mm space required between controller’s top/bottom edges & enclosure walls.
Install at maximum distance from high-voltage cables and power equipment.
UL Compliance
The following section is relevant to Unitronics’ products that are listed with the UL.
The following models: V700-T20BJ is UL listed for Hazardous Locations.
The following models: V700-T20BJ, V700-T4-T20BJ-N, are UL listed for Ordinary Location.
For models from series V700, that include “T4” in the Model name, Suitable for mounting on the flat surface of Type 4X enclosure.
For examples: V700-T20BJ will be modified V700-T4-T20BJ
Question and Answer IconNeed help?

Do you have a question about the Vicpas Vision V1210-T20BJ and is the answer not in the manual?

Summary

General Description and Features

I;O Options

Lists available I/O module options for the controller.

Screen and Input Keys

Specifies the screen type and keypad availability for the HMI.

Built-in Communication Ports

Details the built-in communication ports like RS232/485, Ethernet, USB.

Optional Communication Ports

Describes optional ports that can be added by the user.

Standard Kit Contents and Safety

Standard Kit Components

Confirms the inclusion of the controller, terminal block, battery, and mounting hardware.

Alert Symbols and General Warnings

Explains alert symbols for danger, warning, and caution with safety instructions.

Environmental Considerations

Lists environmental conditions to avoid and specifies ventilation requirements.

UL Compliance Overview

Details UL listing for hazardous/ordinary locations and enclosure compatibility.

UL Ratings and Mounting

UL Ordinary Location Requirements

Specifies panel mounting for UL ordinary locations on Type 1 or 4X enclosures.

Hazardous Location Ratings

Defines suitability and critical warnings for Class I, Division 2 hazardous locations.

Panel Mounting for Hazardous Locations

Details panel mounting requirements to meet UL hazardous location standards.

Memory and Battery Handling

Clarifies USB/SD card usage and safety for battery replacement.

Physical Installation and Wiring

Controller Dimensions

Provides detailed physical dimensions of the Vision controller unit.

Panel Mounting Procedure

Step-by-step instructions for securely mounting the controller into a panel.

I;O Module Installation

Instructions for installing and removing Snap-in I/O modules.

Power, Wiring, and Grounding

Battery Insertion

Procedure and safety precautions for inserting the battery.

General Wiring Safety

Essential safety warnings and precautions for all wiring tasks.

Wiring and Power Supply Guidelines

Detailed wiring procedures and power supply requirements.

Earthing the PLC+HMI

Instructions for proper grounding to maximize system performance and minimize interference.

Communication Interfaces

Communication Port Overview

Lists built-in and optional communication ports.

Port 1 Configuration (RS232;RS485)

Details for Port 1 and how to switch between RS232 and RS485 via DIP switches.

USB and Ethernet Ports

Information on USB port usage and Ethernet connectivity.

Technical Specifications

Power Supply and Display Specs

Details input voltage, current consumption, and graphic display parameters.

Program Memory and Data Storage

Information on memory types, capacities for logic, data, and HMI.

Advanced Features and Specifications

Removable Memory Support

Details compatibility and usage for micro-SD cards.

Communication Port Technical Data

Technical specifications for Port 1, Ethernet, and optional Port 2.

I;O Expansion Capabilities

Methods for expanding I/O capabilities using local and remote modules.

Miscellaneous Features

Details on Real-Time Clock, battery backup, dimensions, and weight.

Environmental Specifications

Temperature and Humidity Ratings

Specifies operational and storage temperature ranges and humidity limits.

Mounting, Altitude, and Vibration

Describes mounting method, operational altitude, and vibration resistance.

Vicpas Vision V1210-T20BJ Specifications

General IconGeneral
BrandVicpas
ModelVision V1210-T20BJ
CategoryTouchscreen
LanguageEnglish