Section One
Introduction
Warning
Read this Manual carefully before use the Instrument.
Generalization
The instrument is a multifunctional earth resistance/earth resistivity tester equipped with a microcomputer.
The instrument employs digital signal settlement technology, which can draw earth measurement signals,
possess features of high frequency, high accuracy and high resistance, and measure earth resistance/ earth
resistivity accurately. The instrument can execute standard 3POLE and 4POLE earth resistance measurements and
has 2POLE earth resistance measurement and earth resistivity calculation functions as well.
The Instrument conforms to the following Safety Requirements:
IEC61010-1CAT 600V,POLUTION degreeⅡ)
IEC61557-1, 5(Electronic safety requirements for low voltage distribution system below AC 1000V and DC
1500V)
Basic Measurement Function
2/3/4- pole earth resistance measurement, Earth resistivity ρcalculation
Earth Resistance Measurement employs AC simulation test, 4-kind of testing frequencies94Hz, 105Hz, 111Hz,
128Hz,which are selectable by hand to reduce impacts from low interference sources.
Auxiliary Earth Resistance Measurement Function
Testing and displaying auxiliary earth resistance.
Warning Display Function for auxiliary earth resistance upper-limits
Displaying warnings for inaccurate measurements due to high auxiliary earth resistances
Auto-range Function in Resistance Measurement and >1999 displays for over range.