Victron energy Color Control GX - Q11: How long should an automatic update take?; Q12: I have a VGR with IO Extender, how can I replace this with a Color Control GX?; Q13: Can I use Remote VEConfigure, as I was doing with the VGR2?; Q14: The Blue Power Panel could be powered through the VE.Net network, can I also do that with a Color Control GX?

Victron energy Color Control GX
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Last update: 2020-10-15 10:33 ccgx:ccgx_faq https://www.victronenergy.com/live/ccgx:ccgx_faq
https://www.victronenergy.com/live/ Printed on 2020-10-15 20:48
Q11: How long should an automatic update take?
The size of the download typically is around 90MB. After download it will install the files which can
take up to 5 minutes.
Q12: I have a VGR with IO Extender, how can I replace this with a Color
Control GX?
It is not yet possible to replace the IO Extender functionality.
Q13: Can I use Remote VEConfigure, as I was doing with the VGR2?
Yes, see VE Power Setup manual
Q14: The Blue Power Panel could be powered through the VE.Net network,
can I also do that with a Color Control GX?
No, a Color Control GX always needs to be powered itself.
Q15: What type of networking is used by the Color Control GX (TCP and UDP
ports)?
Basics:
The Color Control GX needs to get a valid IP address from a DHCP server, including a working
DNS server and gateway, or a static IP configuration.
DNS port 53 UDP and TCP
NTP (time sync) UDP port 123
VRM Portal:
Data to the VRM Portal is sent via HTTP POST and GET requests to
https://ccgxlogging.victronenergy.com on port 443, with a user configurable override to use
plain HTTP on port 80. Note that, even when configured to use plain HTTP, some outgoing
requests will always use HTTPS on port 443.
Firmware updates:
The CCGX connects to https://updates.victronenergy.com/ on port 443.
Remote support (default disabled):
When enabled, an outbound SSH connection to supporthosts.victronenergy.com is maintained.
The CCGX will try to connect on port 22, 80 and 443, and the first that works is maintained.
Enabling Remote Support also enables the sshd daemon, listening for incoming SSH requests on