If the green inverter LED is on and the red Alarm LED is on, reduce the AC load.
What to do if the green inverter LED is on and the red Alarm LED is on in my Victron energy Phoenix Smart Inverter?
If the green inverter LED is on and the red Alarm LED is on, reduce the AC load.
What to do if the green inverter LED is blinking with a fast double pulse and the red Alarm LED is on in my Victron energy Inverter?
If the green inverter LED is blinking with a fast double pulse and the red Alarm LED is on, remove the cause of the overload and then restart the inverter by switching it off and then back on again.
What does it mean when the red Alarm LED is fast blinking on my Victron energy Inverter?
If the green Inverter LED is on and the red Alarm LED is fast blinking, reduce the DC input voltage, check if the battery voltage is correct and if the battery bank is wired correctly. Also check if there perhaps are faulty or incorrect chargers or equipment with a faulty charge regulator.
What to do if the green inverter LED is blinking with a fast double pulse and the red Alarm LED is fast blinking on my Victron energy Phoenix Smart Inverter?
If the green inverter LED is blinking with a fast double pulse and the red Alarm LED is fast blinking, reduce the DC input voltage, check if the battery voltage is correct and if the battery bank is wired correctly. Also check if there perhaps are faulty or incorrect chargers or equipment with a faulty charge regulator. The inverter will automatically turn back on when the battery voltage has dropped to an acceptable level.
What does it mean if the green inverter LED is blinking with a fast double pulse and the red Alarm LED is blinking with a double pulse on my Victron energy Inverter?
If the green inverter LED is blinking with a fast double pulse and the red Alarm LED is blinking with a double pulse, wait until the inverter has cooled down. The inverter will automatically turn back on when its internal temperature has dropped to an acceptable level. Check the environment of the inverter, can the ventilation be improved, or can the inverter be moved to a cooler location?
What should I check if the Alarm LED is blinking with a fast single pulse on my Victron energy Phoenix Smart Inverter?
If the green Inverter LED is on and the Alarm LED is blinking with a fast single pulse, check if all battery cable connections have been tightened. Do the battery cables have a sufficient thickness? DC ripple is related to a voltage drop over the battery cables.
What to do if the green inverter LED is blinking with a fast double pulse and the red Alarm LED is slowly blinking on my Victron energy Phoenix Smart Inverter?
If the green inverter LED is blinking with a fast double pulse and the red Alarm LED is slowly blinking, charge the battery or switch the inverter off and then back on again to restart the inverter. Check the battery voltage at the battery terminals of the inverter. Also check the DC fuses, cables, and cable connections.
What does it mean if the green inverter LED is blinking with a fast double pulse and the Alarm LED is blinking with a fast single pulse on my Victron energy Inverter?
If the green inverter LED is blinking with a fast double pulse and the Alarm LED is blinking with a fast single pulse, check if all battery cable connections have been tightened. Do the battery cables have a sufficient thickness? DC ripple is related to a voltage drop over the battery cables. To restart the inverter switch the inverter off and then back on again.
What to do if the green inverter LED is blinking and the red Alarm LED is blinking on my Victron energy Inverter?
If the green inverter LED is blinking and the red Alarm LED is blinking, retry the firmware update.
Model | Phoenix Inverter Smart |
---|---|
Output Voltage | 230V |
Output Waveform | Pure Sine Wave |
Transfer Time | 20ms |
Communication | Bluetooth |
Remote on-off | Yes |
Output Frequency | 50Hz or 60Hz |
Output Power | 375VA |
Input Voltage Range | 9.5V-17V (12V model), 19V-33V (24V model), 38V-66V (48V model) |
Protection | Overload, Short circuit, Overtemperature |
Dimensions | Varies by model |
Weight | Varies by model |
Humidity | 95% non-condensing |
Input Voltage | 12V, 24V, 48V |
Details on inverter reliability, startup power, and ECO mode functionality.
Understanding LED indicators for operational status and alarms.
Using the VictronConnect app for monitoring and configuration.
Built-in Bluetooth for wireless communication with the app.
Connecting to devices via the VE.Direct port for data transfer.
Methods for remotely controlling the inverter's on/off state.
Utilizing the programmable relay for external control functions.
Guidelines for selecting the installation location and mounting the unit.
Requirements for choosing a suitable and safe installation location.
Step-by-step instructions for physically mounting the inverter.
Detailed instructions for electrical connections and wiring.
Proper connection of battery cables, including sizing and safety.
Connecting solar panel wires to the inverter's PV terminals.
Ensuring correct grounding of the inverter chassis for safety.
Wiring and usage of the remote connector for on/off control.
Connecting external devices via the VE.Direct port.
Connecting external circuits to the programmable relay.
Setting the inverter's AC output voltage and frequency parameters.
Configuring ECO mode for power saving and standby operation.
Adjusting low battery shutdown and charge detect voltage levels.
Using dynamic cut-off for intelligent low battery shutdown.
Configuring the programmable relay for various operational states.
Procedure for updating the inverter's firmware version.
Restoring inverter settings to their original factory defaults.
Methods for turning the inverter on, off, and entering ECO mode.
Operating the inverter using the front panel push button.
Using the main power switch on 5kVA models.
Activating and understanding the inverter's ECO mode.
Interpreting LED indicators and troubleshooting common issues.
Inverter protection mechanisms and automatic restart behaviors.
Monitoring inverter status and parameters using the VictronConnect app.
Remote monitoring using GX devices, GlobalLink, and the VRM portal.
Detailed technical specifications and performance data for the inverter.
Diagrams showing connection points for various inverter models.
Floating ground installation details for 1600VA and 2000VA models.
Floating ground installation details for 3000VA and 5000VA models.
Physical dimensions and mounting diagrams for 1600VA/2000VA models.
Physical dimensions and mounting diagrams for the 3000VA (12V) model.
Physical dimensions and mounting diagrams for 3000VA (24V/48V) models.
Physical dimensions and mounting diagrams for the 5000VA model.