8
Use relay
in alm
If enabled, the relay contacts will be closed
during an alarm condition.
No
Overview
setup
See chapter 4.3.
Power
saving
See below.
Access
level
Set this to “User and install” during
configuration, and “User” during normal
operation.
User and
install
Software
version
The firmware version of the Blue Power Panel N/A
Device
address
The address used by this device for
communication on the network.
N/A
Restart
panel
This option can be used to restart the Blue
Power Panel, and redetect the VE.Net system.
No
Restrict
access
OEM installers can lock the access level of the
Blue Power Panel to prevent users from
changing settings. For more information contact
Victron Energy.
No
Power saving menu
Item Description Default
Value
Backlight
off
Switch the backlight off after a certain period of
inactivity.
10
seconds
Display off
Switch the display off after a certain period of
inactivity.
Never
4.3 Overview configuration
Use the options in the ‘Overview setup’ submenu to configure the
overview screen. First decide which type of overview will be used
(system, generator, or custom). Next, enter the corresponding submenu
and set the configuration options as required.