Do you have a question about the Victron Energy Quattro and is the answer not in the manual?
Efficiency | Up to 96% |
---|---|
Parallel operation | Yes, up to 6 units |
AC Connection | Screw terminals |
Output voltage | 230VAC or 120VAC (depending on model) |
Frequency | 50Hz or 60Hz (depending on model) |
Operating temperature range | -40°C to +65°C |
Battery Charger | Yes, integrated |
Protection | Overload, Short circuit, High temperature, Battery over voltage, Battery low voltage |
Communication | VE.Bus, VE.Direct |
Battery voltage | 24V / 48V |
Details the 3000VA inverter with 100A charger, programmed for 300Ah batteries with 60A max output, and its two 240V outputs.
Explains the function of buttons (a-g) and the display panel (h) for operating the Quattro system.
Details operation when not connected to 240V mains or generator, noting appliance limitations due to high current draw.
Instructions for plugging the 240V 15amp power lead into an external power supply for operation.
Details turning off appliances and the system via button (b) before disconnecting mains to prevent battery drain.
Covers connecting and operating the Quattro with a generator, including initial steps and power availability.
Warning against starting or shutting down generators under load with appliances like the roof A/C to prevent system damage.
Explains how generator output voltage stabilizes for AC Out 2, enabling appliances like roof A/C and refrigerators.
Details turning off appliances and the Quattro before shutting down the generator to prevent damage and battery drain.