EasyManua.ls Logo

Viessmann MPA51 - Page 21

Viessmann MPA51
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Fault
code
*1
Display System charac-
teristics
Cause Measures
F 54 F 54 PWM values in-
correct
EEPROM of
memory stick
modified or de-
leted. Memory
stick faulty
Replace memory
stick.
I
Danger
Plug-in termi-
nals on the
burner control
unit are 'live'.
Only replace
memory stick
when burner
control unit
has been iso-
lated from
power supply.
F 55 F 55 Parameter memo-
ry stick fault
Memory stick faul-
ty
Replace memory
stick.
I
Danger
Plug-in termi-
nals on the
burner control
unit are 'live'.
Only replace
memory stick
when burner
control unit
has been iso-
lated from
power supply.
*1
All fault codes are saved to the fault memory and the last 10 can be called up.
Diagnosis
Diagnosis
(cont.)
5782 991 GB
Service