EasyManua.ls Logo

Viessmann VITOCAL 300-A - Electrical installation scheme

Viessmann VITOCAL 300-A
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection changeover heating/cooling circuit "Heating/cool-
ing" via switching module
AM heat/cool
qCP
R6
211.5
2
1
3
4
5
6
7
8
9
c
d
e
f
230 V/50 Hz
3
5
2
1
N
N
RF
TA
M
1~
STA
M
1~
STA
RTH
qCQ
qCW
qCW
2
R1
ID: 4605229_1304_08
Connections in internal unit and power supply for instantaneous heating water heater
N1
1 / N / PE
230 V/50 Hz
N1
N1
L1
4
L1
L1
3 / N / PE
400 V/50 Hz
N
L2
4
L3
L1
230 V
400 V
Instantaneous heating water heater power supply
Heat pump control unit power supply
2
1 / N / PE
230 V/50 Hz
F1 6.3AH (slow)
L1
N
X40
L1
N
ID: 4605229_1304_08
Vitocal 200-S/222-S/242-S
(cont.)
System examples
VIESMANN
133
5822 472 GB
5