34
Set-Function format
6HQG&RPPDQG7\SH ´V´
Name Length ID Command
Type
Command Value1 Value2 Value3 CR
Byte
Count
1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes
order
12~3 4 5 6 7 8 9
NOTE:
For VT2405LED-1 and VT3205LED, the set “Power on” command is the exception.
5HSO\&RPPDQG7\SH ´´RU³´
Name Length ID Command
Type
CR
Byte
Count
1 Byte 2 Byte 1 Byte 1 Byte
Bytes
order
12~3 4 5
NOTE:
1. The reply for “Power on” command is the exception for VT2405LED-1 and
VT3205LED. It’s 0x322B0D ( 2+<CR>).
2. When PC applies command to all displays (ID=99), only the #1 set needs to reply
by the name of ID=1.
Example1: Set Brightness as 76 for TV-02 and this command is valid
6HQG+H[)RUPDW
Name Length ID Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38 0x30
0x32
0x73 0x24 0x30 0x37 0x36 0x0D
5HSO\+H[)RUPDW
Name Length ID Command
Type
CR
Hex
0x34 0x30
0x32
0x2B 0x0D
Example2: Set Brightness as 176 for TV-02 and this command is NOT valid
6HQG+H[)RUPDW
Name Length ID Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38 0x30
0x32
0x73 0x24 0x31 0x37 0x36 0x0D