- 25 –
ViewSonic Corporation
Confidential - Do Not Cop VA1721wmb
(4)、Adjust the RED of color3 on factory window until CA-210 indicator reached the
value R=100
(5)、Adjust the GREEN of color3 on factory window until CA-210 indicator reached the
value G=100
(6)、Adjust the BLUE of color3 on factory window until CA-210 indicator reached the
value B=100
(7)、Repeat above procedure ( item 4,5,6) until CA-210 RGB value meet the
tolerance =100±5
D、Adjust 5400 color-temperature
(1) Switch the CA-210 to RGB-Mode (with press “MODE” button )
(2)、Switch the MEM .channel to Channel 1( with up or down arrow on CA-210 )
(3)、The LCD-indicator on CA-210 will show x=0.335±0.03, y=0.350±0.03, Y≥190 cd/m
2
(4)、Adjust the RED of color3 on factory window until CA-210 indicator reached the
value R=100
(5)、Adjust the GREEN of color3 on factory window until CA-210 indicator reached the
value G=100
(6)、Adjust the BLUE of color3 on factory window until CA-210 indicator reached the
value B=100
(7)、Repeat above procedure ( item 4,5,6) until CA-210 RGB value meet the
tolerance =100±5
E、Adjust SRGB color-temperature
(1)、Switch the CA-210 to RGB-Mode (with press “MODE” button )
(2)、Switch the MEM .channel to Channel 1 ( with up or down arrow on CA-210 )
(3)、The LCD-indicator on CA-210 will show x=0.313±0.03, y=0.329±0.03, Y≥190 cd/m
2
(4)、Adjust the RED of color3 on factory window until CA-210 indicator reached the
value R=100
(5)、Adjust the GREEN of color3 on factory window until CA-210 indicator reached the
value G=100
(6)、Adjust the BLUE of color3 on factory window until CA-210 indicator reached the
value B=100
(7)、Repeat above procedure ( item 4,5,6) until CA-210 RGB value meet the tolerance
=100±5
F、Press reset key and Turn the Power-button “off to on” to quit from factory mode.
2. Geometry
1).Set cross-hatch pattern and preset timing as timing table listed.
2).Change to each mode in turn and wait for the monitor finish auto-alignment and save
press before change to next mode.
3).Until all of modes are adjusted, exit OSD menu and press POWER OFF to exit factory
mode.