§ Table 5-1 outlines the Get-function command list that must be supported by the LCD
Monitor.
Table 5-1: PC Get-function command to LCD Monitor
Get Function Length ID Command
Type
Command
Code
(ASCII)
Command
Code
(Hex)
Response Range
(Three ASCII bytes)
Comments
Get-Contrast 8 g a 61 000 ~ 100 Gets Contrast value
Get-Brightness 8 g b 62 000 ~ 100 Gets Brightness value
Get-Sharpness 8 g c 63 000 ~ 100 Gets Sharpness value
Get-Color 8 g d 64 000 ~ 100 Gets Color value
Get-Tint 8 g e 65 000 ~ 100 Gets Tint value
Get-Volume 8 g f 66 000 ~ 100 Gets Volume value
Get-Mute 8 g g 67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF
status
Get-Input select 8 g j 6A
000: TV
001: AV
002: SV
003: YPBPR
004: DVI
005: HDMI
006: VGA
Gets Input select status
Get-Power
status:STBY
6 n/a g l 6C 000
Get-Power
status:ON
8 g l 6C 001
Get-Remote
Control
8
g n 6E
000: DISABLE
001: ENABLE
002: PASS
THROUGH
Gets RCU mode status
Get-Power
Lock
8 g o 6F
000: Unlock
001: Lock
Get-Button
Lock
8 g p 70
000: Unlock
001: Lock
Get-Menu Lock 8 g q 71
000: Unlock
001: Lock
Get-Setup
wizard
8 g s 73
000: Disable
001: Enable
Get-ACK 8 g z 7A 000
This command is
used to test the
communication link.