Quick Programming Features (after accessing the Touch Tone Programming Mode)
DESCRIPTION DIGITS +
MEMORY
LOCATION
First speed dial number 0-32 digits + #00
Second speed dial number 0-32 digits + #01
Third speed dial number 0-32 digits + #02
Fourth speed dial number 0-32 digits + #03
Fifth speed dial number 0-32 digits + #04
To clear any speed dial number (no digits) + #00 - #04
Talk/Listen Delay (VOX) (.1 to .9 sec, factory set to .5 sec) 1 digit (1-9) + #11
Call Length Time Out (0 to 9 min, 0 = disabled, factory set to 3 min) 1 digit (0-9) + #12
Lap Counter (0 to 9, 0 = disabled, factory set to 0) 1 digit (0-9) + #16
Dial Next Number on Ring No Answer (0 or 1 = disabled, 2 - 9 = number of rings, factory set to 7) 1 digit (0-9) + #17
Dial Next Number on Busy (0 or 1, 0 = disabled, factory set to 1/enabled) 1 digit (0 or 1) + #18
Security code (factory set to 845464) 6 digits (0-9) + #19
Identification number (1-6 digits, blank = disabled, factory set to 987654) 0-6 digits (0-9) + #20
Access Code (1-6 digits, blank = disabled, factory set to 123456) 0-6 digits (0-9) + #21
Microphone volume (0-9, 0 = ANC, factory set to 5) 1 digit (0-9) + #22
Speaker Volume (0-9, factory set to 5) 1 digit (0-9) + #23
Relay Activation Command ( 1 or 2 digits, QQQQ = QQ, Q#Q# = ##, 0-9 or 00-99, factory set to
QQ) (Relay Mode must be set to 0 = Door Strike)
1 or 2 digits + #24
Relay Activation Time (2 digits, 00-99 sec, 00= 0.5 sec, factory set to 05) 2 digits (00-99) + #25
Relay Mode (0 = Door Strike, 1 = Outbound Call, 2 = In/Outbound Call, 3 = Doorbell, 4 = LV-1K
Control, factory set to 0)
1 digit (0-4) + #26
Relay Activation Tone (Buzz) Volume (1 digit 0-3, 0 = off, factory set to 3) 1 digit (0-3) + #27
In-Band Audio Detection Sensitivity (1-9, 1 = min, 9 = max, factory set to 5, power cycle unit after setting) 1 digit (1-9) + #28
In-Band Audio Call Progress Detection (0 or 1, 0 = OFF, 1 = ON, factory set to 0) 1 digit (0 or 1) + #29
“Call” LED Control
(0 or 1, 0 = Automatic, 1 = Called Party Control / Q entered to light LED, factory set to 0)
1 digit (0 or 1) + #30
Speaker Mode (0, 1 or 2, 0 = OFF/Silent Monitor, 1 = ON, 2 = OFF Until Answered, factory set to 1) 1 digit (0-2) + #31
LED Mode
(1 digit 0-3 0 = OFF/Silent Monitor, 1 = Entry Phone, 2 = Emergency Phone 3 = Emergency
phone outbound only, factory set to 1)
1 digit (0-3) + #32
Auto Answer / Loud Ring (0, 1 or 2, 0 = Disabled, 1 = Auto Answer, 2 = Loud Ring, 3 = Loud Ring with AGC,
factory set to 1)
1 digit (0-3) + #33
DESCRIPTION ENTER DIGITS
Diagnostic tones (used to check mic and speaker operation)
Q0
Enable Alternate Switch Action (factory setting)
Q1
Disable Alternate Switch Action
Q2
Enable Relay Latching Commands (factory setting)
Q6
Disable Relay Latching Commands
Q7
To add a Q at any point in the dialing string
QQ
To add a # at any point in the dialing string
Q#
Reset all Quick Programming Features to factory default settings ###