BBAASSIICC SSPPEECCIIFFIICCAATTIIOONNSS
IINNTTEERRIIOORR AANNDD EEXXTTEERRIIOORR PPOOWWEERR HHOOOODDSS
RREECCOOMM.. NNUUMMBBEERR OOFF 225500 WWAATTTT 112200VVAACC//6600HHzz
DDEESSCCRRIIPPTTIIOONN CCFFMM
11
HHAALLOOGGEENN HHEEAATT LLAAMMPPSS FFIILLTTEERRSS SSPPAACCEERRSS MMAAXX.. AAMMPPSS33
((iinntt..--iinntteerriioorr;; eexxtt..--eexxtteerriioorr)) LLIIGGHHTTSS ((SSoolldd SSeeppaarraatteellyy)) CCeenntteerr LLHH RRHH ((IInntteerriioorr//EExxtteerriioorr))
30” W. 300 int./600 int./900 ext./1200 ext. 2 1 2 0 1 1 3.9/6.0/8.7/6.0
36” W. * 300 int./600 int./900 ext./1200 ext. 2 1 2 1 1 1 3.9/6.0/8.7/6.0
42”W.* 600 int./900 ext./1200 ext. 2 1 2 1 1 1 6.0/8.7/6.1
48” W. 1200 int./1200 ext./1500 ext. 3 2 2 1 1 1 11.5/8.5/9.2
54” W. 1200 int./1200 ext./1500 ext. 3 2 3 2 1 1 11.5/8.5/9.2
60” W. 1200 int./1200 ext./1500 ext. 4 2 3 2 1 1 11.9/8.9/9.7
66” W. 1200 int./1200 ext./1500 ext. 4 2 3 0 1 1 11.9/8.9/9.7
RREECCOOMMMMEENNDDEEDD MMAAXX.. DDUUCCTT
MMOODDEELL NNUUMMBBEERR CCFFMM
11
DDUUCCTT SSIIZZEE RRUUNN
22
((fftt..))
FFoorr UUssee wwiitthh hhooooddss::
DIV300 (interior) 300 7” round 50
DIV600 (interior) 600 7” round 50
DIV1200 (interior) 1200 10” round 50
DEV900 (exterior) 900 10” round 50
DEV1200 (exterior) 1200 10” round 50
DEV1500 (exterior) 1500 10” round 75
PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE
FROM ANY VENTILATION PRODUCT
1. •All CFMs stated are based on tests at .1 static pressure: without applying static pressure, CFM would be greatly
overstated.
2. •Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and
trained installer.
•Straight runs and gradual turns are best; for example, each 90o elbow is equivalent to 5-10 feet (1.52 - 3.05 cm)
of straight run.
•Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
•Check with a qualified and trained installer or local codes for makeup air requirement, if any.
3. •Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct
with 2-wire with ground.
**11220000 oorr 11550000 CCFFMM eexxtteerriioorr vveennttiillaattoorr sshhoouulldd bbee uusseedd wwhheenn iinnssttaalllleedd oovveerr rraannggeess//rraannggeettooppss wwiitthh ggaass ggrriillll..
RREECCOOMM.. NNUUMMBBEERR OOFF 112200VVAACC//6600HHzz
DDEESSCCRRIIPPTTIIOONN CCFFMM
11
HHAALLOOGGEENN FFIILLTTEERRSS SSPPAACCEERRSS MMAAXX.. AAMMPPSS33
((iinntt..--iinntteerriioorr;; eexxtt..--eexxtteerriioorr)) LLIIGGHHTTSS CCeenntteerr LLHH RRHH ((IInntteerriioorr//EExxtteerriioorr))
36” W.* 600 int./900 ext./1200 ext. 4 4 2 2 2 3.9/6.6/3.9
42”W.* 600 int./900 ext./1200 ext./1500 ext. 4 4 2 2 2 4.7/7.4/4.8/5.5
54” W. 1200 int./1200 ext./1500 ext. 6 6 2 2 2 8.6/5.6/6.4
66” W. 1200 int./1200 ext./1500 ext. 8 8 2 2 2 9.5/6.5/7.3
2
WWAALLLL HHOOOODDSS
IISSLLAANNDD HHOOOODDSS