25
SW24.W
LOAD
Restore default values and loading from
memory card
Sub
menu
Description Msg
display
DEF
Loading the default values
Waiting press OK for 5 s to load
the default values.
oooo
Note:
Loading the default values then requires the
travel to be calibrated again, LRNT ashes
on the display until (rapid or advanced)
calibration is done.
MEM
Loading the programming from
memory card
Waiting press OK for 5 s to load
the values from memory card."
oooo
Loading from memory card com-
pleted OK.
DONE
Loading from memory card error
(e.g. no card).
EMEM
PASS
Control panel protection level settings
(default = OFF)
OFF No protection
1
Protection of menus MOT, LRNT, TRV, OUT,
IN, LGC, STAT, EXP, LOAD
2 Protection of menu RAD
3
Protection from IP connection (it is not
possible to connect to the control panel from
a smartphone)
4
Protection of menus MOT, LRNT, TRV,
OUT, IN, LGC, STAT, EXP, LOAD and IP
connection
5 Protection of menu RAD and IP connection
6 Complete control panel protection
7
Protection of all board menus, IP connection
available
Note:
The password must be entered in the control panel each
time you wish to access a protected menu. If the pass-
word entered is incorrect access to the menu is denied.