QT-C 040714
Page 12 | 1-800-343-9463
Button/Symbol Normal Functions
ON/OFF
Press and hold the on/o button for approximately 3 seconds to turn the cooling system on or o.
Note: This does not disconnect power from the cooling system. In order for the power to be
shut o from the cooling system, the power cord must be unplugged from the wall receptacle.
This button also serves as an escape button.
Up and Down
Use these buttons to scroll up or down a menu.
Press and hold the up button for approximately ve seconds to manually start the defrost
sequence.
SET
Press the set button once to view the set point, temperature of the bottle probe.
Once the set button is pressed “SET will be displayed. Press the up or down arrows to scroll
through PB1 and the set point parameter.
Press the set button again to view any of these values.
To change the set point, press the set button when “SET is displayed on the screen. The current
set point will be displayed. Use the up or down arrows to change the set point to the desired
temperature. Press the set button again once the desired temperature is reached.
Hold the set button for approximately 5 seconds to enter the CPSM (Customer Preference
Selection Mode) menu. (CPSM detail on next page)
Snowake
Constant - Cooling System is in cooling mode and the compressor and fan(s) are running.
Blinking - The cooling sytem is calling for cooling, but must wait 5 minutes before restarting the
compressor. This 5 minute delay serves as an anti-short cycle for the compressors protection.
Dripping Snowake
Cooling System is in defrost mode. The compressor and fan(s) will be turned o during this cycle.
Compressor is On
Unit is in Defrost Mode
Alarm is Present
Temperature Measurement
Menu Navigation
& Value Increase
*Press and hold
to manually enter
defrost mode.
Power On/O
(hold for approx. 3 seconds)
& Escape
Menu Navigation
& Value Decrease
Probe Value &
Alarm Folder
*Press and hold to
enter the parameter
menu.
CONTROLLER FUNCTIONS