6 WT3SPD 30521E(1)2012-04-10 A
ENGLISH USER MANUAL
TECHNICAL DATA
Model WT3SPD
Voltage V 220-240
Frequency Hz 50-60
Power W 750
Current A 4.5
Fan wheel Diameter mm 241.3
Power settings 3-speed
Fan Speed (L) rpm 1200
Fan Speed (M) 1330
Fan Speed (H) 1410
Flow rate m³/h 5950 / 5440 / 4760
Dimension LxWxH cm 53.3 x 50.8 x 43.2
Weight kg 11.8
Length of Power cord m 6.1
Sound pressure level dB(A) 68
WIRING DIAGRAM
OPERATION
BEFORE STARTING THE MACHINE
Check machine for any obstructions in fan prior to operation.
CAUTION!
Obstruction of the fan.
If an item blocks the intakes of the blower, this will hurt the performance of the blower, and could cause the motor to
overheat.
Remove all obstructions before starting the machine.
BASIC OPERATION
Plug power cord into a grounded outlet.
Do not use an extension cord in conjunction with the standard power cord.
This machine has three power settings. Turn the power knob to the desired speed. High = 3, Med = 2, Low= 1.
To stop the machine at any time, simply turn the power knob to the “0” position.
Never stick any object into the air inlet vents or the air outlet vent.
MAINTENANCE
To keep the machine performing well for many years, please follow the following maintenance procedures.
CAUTION!
Always confirm that the machine is unplugged prior to performing any maintenance or repairs.