What to do if ViscoTec PreeFlow eco-CONTROL EC200 DUO Laboratory Equipment shows 'Dosing system cannot be operated, no display'?
R
robertclarkAug 3, 2025
If the ViscoTec dosing system cannot be operated and there is no display, there are several possible causes. First, ensure the dispenser is properly connected, remembering to remove the mains plug beforehand. Then, check that the mains switch is turned on. Finally, verify that the mains adapter has power and is not defective.
G
Gary RodriguezAug 8, 2025
What to do if ViscoTec PreeFlow eco-CONTROL EC200 DUO Laboratory Equipment displays 'Level of medium critical'?
F
Fernando WhiteAug 8, 2025
If the ViscoTec Laboratory Equipment displays a 'Level of medium critical' error, it indicates that there may not be enough medium in the supply tank. Refill the tank with the medium. If the error message persists, inspect the sensor and sensor input. If necessary, initiate a brief "emergency operation" without level monitoring.
J
Joshua ReyesAug 12, 2025
What to do if ViscoTec PreeFlow eco-CONTROL EC200 DUO Laboratory Equipment shows 'Overcurrent monitoring' error?
W
William WilliamsAug 12, 2025
If the ViscoTec Laboratory Equipment shows an 'Overcurrent monitoring' error, it may be due to dispenser components not running smoothly, potentially caused by hardened medium or dry running. You should dismantle and clean the dispenser, and if necessary, replace the stator.
N
Natalie JohnstonAug 17, 2025
What to do if ViscoTec PreeFlow eco-CONTROL EC200 DUO Laboratory Equipment displays 'Error on sensor A (B)'?
Q
qsanchezAug 18, 2025
If the ViscoTec Laboratory Equipment displays an 'Error on sensor A (B)', the sensor may be faulty or not connected. Check the sensor connection and replace the sensor if necessary.
V
vickidorseyAug 22, 2025
Why does ViscoTec PreeFlow eco-CONTROL EC200 DUO Laboratory Equipment only offer program 00 when trying to save a dosing program?
S
Susan WadeAug 22, 2025
If your ViscoTec Laboratory Equipment only offers program 00 when saving a dosing program, it is likely that no MMC/SD memory card is inserted or the card is not formatted. Insert or format the MMC/SD memory card to resolve this issue.
B
Brenda CalderonAug 27, 2025
What to do if ViscoTec PreeFlow eco-CONTROL EC200 DUO Laboratory Equipment shows 'Motor A (B) not type 450...'?
J
Jack PetersonAug 27, 2025
If the ViscoTec Laboratory Equipment displays 'Motor A (B) not type 450...', it indicates that the incorrect dispenser is connected. Connect the 2K-dispenser eco- DUO 450.