EN - 52
User Manual
Couplers on/off
Data format: F0H 31H 2FH 70H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
70H : coupler
vvH : type and switch
00H=II/P on
10H=II/P off
01H=I/P on
11H=I/P off
03H=II/I on
13H=II/I off
F7H: End of Exclusive
- This message can be only received and
recorded by the internal sequencer. It is not
transmitted.
SYSTEM REAL TIME MESSAGES
FEH: Active Sensing
FEH is transmitted every 300 msec. whenever is
no other MIDI data being transmitted.