IT - 52
Manuale Utente
31H : Viscount ID
2nH : channel number (s=0H–EH)
5CH : 1st tremulant depth
vvH : depth value (04H–20H)
F7H: End of Exclusive
- This message is transmitted when the
Tremulant is switched on.
- When switched off, the tremulant depth
value is trasmitted as 00H
Temperament
Parameter: Temper.
Video page: Main page
Data format: F0H 31H 2FH 31H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
31H : temperament
vvH : temperament type
00H=Equal
10H=Kirnberger II
11H=Werckmeister III
12H=Pythagorean
13H=Meantone 3#
14H=Vallotti
15H=Chaumont
16H=Kellner 1975
17H=Kirnberger III
18H=Werckmeister IV
19H=Werckmeister V
1AH=Silbermann
1BH=Meantone 3b
1CH=Meantone 3M
1DH=Zarlino
1EH=Sauveur 1
1FH=Sauveur 2
20H=Barca
F7H: End of Exclusive
Ensemble
Parameter: Ensemble
Video page: Style
Data format: F0H 31H 2FH 32H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
32H : ensamble
vvH : ensamble value (00H–08H)
F7H: End of Exclusive
Tuning
Parameter: Tuning
Video page: Main page
Data format: F0H 31H 2FH 67H 00H 0nH 0nH
0nH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
67H : fine tuning
0nH 0nH 0nH: nibblezed data of tuning value
02H 00H 0CH=-50 cents (A=427,47Hz)
04H 00H 00H=0 cents (A=440 Hz)
05H 0FH 04H=+50 cents (A=452,89Hz)
F7H: End of Exclusive
Cancel
Data format: F0H 31H 2FH 6CH 00H F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
6CH : cancel
00H : execute cancel
F7H: End of Exclusive
Couplers on/off
Data format: F0H 31H 2FH 70H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
70H : coupler
vvH : type and switch
00H=II/P on
10H=II/P off
01H=I/P on
11H=I/P off
03H=II/I on
13H=II/I off
F7H: End of Exclusive