Do you have a question about the Vitalograph Pneumotrac and is the answer not in the manual?
Accuracy (Volume) | ±3% or 0.05 L, whichever is greater |
---|---|
Parameters Measured | FVC, FEV1, PEF, FEV1/FVC ratio, FEF25-75%, FET |
Connectivity | USB |
Resolution | Flow: 0.01 L/s |
Humidity Range | Up to 95% RH, non-condensing |
Storage Temperature | -20 - 70 °C |
Lists the main components of the Vitalograph Pneumotrac device, including the device itself, flowhead, and tubing.
Details the key features and benefits of the Vitalograph Pneumotrac, such as low cost, accuracy, and hygiene.
Connects one end of the serial cable to an available serial port on the PC, usually marked with a specific symbol.
Connects the other end of the serial cable to the serial port on the Vitalograph Pneumotrac device.
Connects one end of the twin tubing to the Vitalograph Pneumotrac device, ensuring correct ribbed side connection.
Connects the other end of the twin tubing to the flowhead, ensuring correct ribbed side connection to the blue tapping.
Places a flowhead filter into the flowhead holder on the Vitalograph Pneumotrac device.
Confirms the Vitalograph Pneumotrac device is ready for use, pending Spirotrac software installation.
Inserts the Spirotrac CD-ROM to automatically initiate the software installation program.
Prompts the user to select the desired language for the software installation process.
Requires the user to read and agree to the software License Agreement to continue installation.
Allows users to specify the destination drive and directory for the Spirotrac software installation.
Enables selection of optional utilities, like the Database Upgrade Utility, during installation.
Selects the interface DLL required for linking Spirotrac to third-party Data Management Systems.
Identifies the Vitalograph Pneumotrac as the measuring device to be used with the Spirotrac software.
Ensures Adobe Acrobat Reader is installed for viewing user manuals and help files.
Enters the Spirotrac Software Serial Number for security purposes as prompted during installation.
Finishes the installation process by clicking 'Finish' and recommends restarting the computer.
Details the meaning of various symbols used in the manual, such as Type BF equipment and Class II.
Identifies additional labels found on the equipment, such as the serial connector label.
Provides detailed technical specifications for the Vitalograph Pneumotrac, including flow detection, accuracy, and dimensions.
Explains the CE marking, indicating compliance with European Community Medical Devices directive and relevant standards.
Highlights the FDA notice regarding federal law restricting the device's sale to a physician's order.
Outlines the conditions under which Vitalograph Ltd. provides a guarantee for hardware and software.