VIVOTEK
User's Manual - 331
© 2019 VIVOTEK INC. All Right Reserved
194
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ignment" is 1.
lens_ldc_support
<boolean>
0/7
Indicate whether to support lens
distortion correction function.
* We support this parameter when
the version number (httpversion) is
equal or greater than 0309d.
palette_support
<boolean>
0/7
Indicate support color palettes or not.
Thermal cameras provide a choice of
color palettes on the camera, that
help quickly distinguish thermal
variations and patterns in an image.
The color tones correspond to the
apparent surface temperatures of the
target.
* We support this parameter when
the version number (httpversion) is
equal or greater than 0310a.
palette_mode
A list of palette
options
0/7
Palette options used in thermal
surveillance.
*Only available when
"capability_image_c<0~(n-1)>_palette
_support"=1.
* We support this parameter when
the version number (httpversion) is
equal or greater than 0310a.
Group: capability_peripheral_c<0~(n-1)> n denotes the value of "capability_nvideoin"
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
devicecontrol
<boolean>
0/7
Indicate whether to support the
peripheral device control.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0305c.
© 2019 VIVOTEK INC. All Right Reserved
195
7.28 Customized Event Script
Group: event_customtaskfile_i<0~2>
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
name string[40] 6/6 Custom script identification of this
entry.
date string[4~20] 6/6 Date of custom script.
time string[4~20] 6/6 Time of custom script.
7.29 Event Setting
Group: event_i<0~(n-1)> n denotes the value of "capability_nevent"
(capability_nevent > 0)
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
name string[40] 6/6 Identification of this entry.
enable 0, 1 6/6 Enable or disable this event.
priority 0, 1, 2 6/6 Indicate the priority of this event:
“0”= low priority
“1”= normal priority
“2”= high priority
delay 1~999 6/6 Delay in seconds before detecting the
next event.