258
direct,
forward,
backward
Motor’s moving direction.
It works only if function=zoom or function=focus.
Motor’s position.
It works only if function=zoom or function= focus and
direction=direct.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
Motor’s moving steps.
It works only if function=zoom or function=focus and
direction=forward and direction=backward.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
* This parameter is for additional fine-tune, the value is from 1 to
30.
Open iris or not.
It works only if function=auto or function=scan.
© 2019 VIVOTEK INC. All Right Reserved
259
8.20 BackFocus (capability_image_c<0~(n-1)>_remotefocus=4)
Note: This request requires Administrator privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/admin/remotefocus.cgi?function=<value>[&direction=<value>]
[&position=<value>][&steps=<value>][&iris]
PARAMETER VALUE DESCRIPTION