VIVOTEK
User's Manual - 359
© 2020 VIVOTEK INC. All Right Reserved
219
7.34 Region of Interest
Group: roi_c<0~(n-1)> for n channel product and m is the index of video stream which support ePTZ.
(capability_eptz > 0)
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
s<0~(m-1)>_home <W,H>
<product
dependent>
1/6 ROI left-top corner coordinate.* If the
minimal window size is 64x64, then the
"win_i0_home"=(0~resolution_W-64,
0~resolution_H-64), which the resolution
is the value in current stream.
* If the stream doesn’t support ePTZ, the
permissions of this parameter must be
set as 1/7.
s<0~(m-1)>_size <WxH>
<product
dependent>
1/6 ROI width and height. The width value
must be multiples of 16 and the height
value must be multiples of 8
* The minimal window size is 64x64, and
then resolution_W, resolution_H is the
value in current stream.
* If the stream doesn’t support ePTZ, the
permissions of this parameter must be
set as 1/7.
7.35 ePTZ Setting
Group: eptz_c<0~(n-1)> for n channel product. (capability_eptz > 0)
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
osdzoom
<Not recommended to
use this>
<boolean> 1/4 Indicates multiple of zoom in is
“on-screen display” or not.
* Reserved for compatibility, and suggest
don't use this since [httpversion] > 0302a
* We replace
"eptz_c<0~(n-1)>_osdzoom" with "
videoin_c<0~(n-1)>_zoomratiodisplay".
smooth <boolean> 1/4 Enable the ePTZ "move smoothly"
feature
© 2020 VIVOTEK INC. All Right Reserved
220
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
tiltspeed -5 ~ 5 1/7 Tilt speed
(It should be set by eCamCtrl.cgi rather
than by setparam.cgi.)
panspeed -5 ~ 5 1/7 Pan speed
(It should be set by eCamCtrl.cgi rather
than by setparam.cgi.)
zoomspeed -5 ~ 5 1/7 Zoom speed
(It should be set by eCamCtrl.cgi rather
than by setparam.cgi.)
autospeed 1 ~ 5 1/7 Auto pan/patrol speed
(It should be set by eCamCtrl.cgi rather
than by setparam.cgi.)
7.35.1. ePTZ Settings for Each Stream
Group: eptz_c<0~(n-1)>_s<0~(m-1)> for n channel product and m is the index of video stream.
(capability_eptz > 0)
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
patrolseq string[120] 1/4 The patrol sequence of ePTZ. All the
patrol position indexes will be separated
by ","
patroldwelling string[160] 1/4 The dwelling time (unit: second) of each
patrol point, separated by “,”.
preset_i<0~19>_name string[40] 1/7 Name of ePTZ preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_pos <W,H>
<product
dependent>
1/7 Left-top corner coordinate of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)