EasyManua.ls Logo

Vivotek IB9367-EHT-v2 - Page 375

Vivotek IB9367-EHT-v2
442 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
User's Manual - 375
© 2020 VIVOTEK INC. All Right Reserved
235
NAME VALUE SECURITY
(get/set)
DESCRIPTION
Set -1 to disable all the tour
groups.
tour_i<0~19>_name string[40] 1/4 Name of the tour.
tour_i<0~19>_type <boolean> 1/4 0 = Recorded tour
1 = Preset tour
tour_i<0~19>_speed -5 ~ 5 1/4 Preset tour: pan and tilt speed
when moving between presets.
Recorded tour: unnecessary.
tour_i<0~19>_direction forward,backward,ra
ndom
1/4 User can choose which direction
the preset tour goes.
"forward": preset tour goes in
forward order.
"backward": preset tour goes in
backward order.
"random": the presets of the tour
will be recalled randomly.
* Only available when
"capability_presettourdirection"
is 1.
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0307a.
tour_i<0~19>_checklist string[512] 1/4 The indexes of preset positions,
separated by “,
tour_i<0~19>_dwelltim
e
string[512] 1/4 Preset tour: time to wait before
moving to the next preset
position, separated by “,
Recorded tour: number of
seconds to wait
before continuing a loop tour.
P
LEASE REFER TO PTZ CONTROL API
7.42 UART Control
© 2020 VIVOTEK INC. All Right Reserved
236
Group: uart (capability_nuart > 0 and capability_fisheye = 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] 1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128] 1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 1/4 Enable HTTP tunnel channel to control
UART.
Group: uart_i<0~(n-1)> n is uart port count (capability_nuart > 0 and capability_fisheye = 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
baudrate 300,600,1200,2400,
4800,9600,19200,38
400,57600,115200
4/4 Set baud rate of COM port.
databit 5,6,7,8 4/4 Data bits in a character frame.
paritybit none,
odd,
even
4/4 For error checking.
stopbit 1,2 4/4 "1": One stop bit is transmitted to
indicate the end of a byte.
"2": Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
uartmode rs485,
rs232
4/4 RS485 or RS232.
customdrvcmd_i<0~
9>
string[128] 1/4 PTZ command for custom camera.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_n
ame
string[40] 1/4 Additional PTZ command name.
* only available when
capability_camctrl_c0_rs485=2

Related product manuals