EasyManua.ls Logo

Vivotek IB9367-EHT-v2 - Page 402

Vivotek IB9367-EHT-v2
442 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
402 - User's Manual
© 2020 VIVOTEK INC. All Right Reserved
263
PARAMETER VALUE DESCRIPTION
state while “1” means
active or triggered state.
Where "nstate" is next
state after duration.
Ex: vi0=0(200)1
Setting virtual input 0 to normal state, waiting 200
milliseconds, setting it to trigger state.
Note that when the virtual input is waiting for next
state, it cannot accept new requests.
return <return page> Redirect to the page <return page> after the
parameter is assigned. The <return page> should
be the relative path according to the root of
camera. If you omit this parameter, it will redirect
to an empty page.
* If the <return page> is invalid path, it will ignore
this parameter.
Return Code Description
200 The request is successfully executed.
400 The request cannot be assigned, ex. incorrect parameters.
Examples:
setvi.cgi?vi0=0(10000)1(15000)0(20000)1
No multiple duration.
setvi.cgi?vi3=0
VI index is out of range.
setvi.cgi?vi=1
No VI index is specified.
503 The resource is unavailable, ex. Virtual input is waiting for next state.
Examples:
setvi.cgi?vi0=0(15000)1
setvi.cgi?vi0=1
Request 2 will not be accepted during the execution time(15 seconds).
8.18 Open Timeshift Stream (capability_timeshift > 0,
timeshift_enable=1, timeshift_c<n>_s<m>_allow=1)
Note: This request requires Viewer access privileges.
Syntax:
For HTTP push server (MJPEG):