EasyManuals Logo

Vivotek IB9367-EHT-v2 User Manual

Vivotek IB9367-EHT-v2
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #405 background imageLoading...
Page #405 background image
VIVOTEK
User's Manual - 405
© 2020 VIVOTEK INC. All Right Reserved
265
Return Code Description
400 Bad Request Request is rejected because some parameter values are illegal.
415 Unsupported Media Type Returned, if forcechk appears,when minsft is not achievable or
the timeshift feature of the target stream is not enabled.
8.19 RemoteFocus
(capability_image_c<0~(n-1)>_remotefocus=1)
Note: This request requires Administrator privileges.
Method: GET/POST
Syntax: (for control API)
http://<servername>/cgi-bin/admin/remotefocus.cgi?channel=<value>&[function=<value>][&direct
ion=<value>][&position=<value>][&steps=<value>][&iris]
PARAMETER
VALUE DESCRIPTION
channel 0~"capability_nvideoin"-1
Channel of the video source.
function zoom,
focus,
auto,
scan,
stop,
positioning,
irisopen,
irisenable
zoom - Move focus motor
focus – Move focus motor
auto – Perform auto focus
scan – Perform focus scan
stop – Stop current operation
positioning – Position the motors
irisopen – Fully open iris. It will maintain fully open iris
status until sending function=irisenable cgi.
irisenable – return back to user setting status of iris.
direction direct,
forward,
backward
Motors moving direction.
It works only if function=zoom or function=focus.
© 2020 VIVOTEK INC. All Right Reserved
266
PARAMETER
VALUE DESCRIPTION
position <motor_start> ~
<motor_end>
Motors position.
It works only if function=zoom or function= focus and
direction=direct.
<motor_start> : remote_focus_zoom_motor_start or
remote_focus_focus_motor_start,
<motor_end> : remote_focus_zoom_motor_end or
remote_focus_focus_motor_end replied from
"function=getstatus"
steps 1 ~ 30 Motors moving steps.
It works only if function=zoom or function=focus and
direction=forward and direction=backward.
* Motor will stop when it reaches to <motor_start> or
<motor_end>.
* This parameter is for additional fine-tune, the value is
from 1 to 30.
iris N/A Open iris or not.
It works only if function=auto or function=scan.
Syntax: (for query API)
http://<servername>/cgi-bin/admin/remotefocus.cgi?channel=<value>&[function=<value>]

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivotek IB9367-EHT-v2 and is the answer not in the manual?

Vivotek IB9367-EHT-v2 Specifications

General IconGeneral
BrandVivotek
ModelIB9367-EHT-v2
CategorySecurity Camera
LanguageEnglish

Related product manuals