Charger module is malfunctioning;
see Troubleshooting Charger
Malfunction
Off
Solid
Yellow or
Amber
Normal Condition: the battery may
not be inserted into the charger
correctly. Reinsert the battery into
the charger.
If the condition persists, the battery
may be too hot or too cold.
The charger waits for the battery to
warm up or cool off before it begins
charging (at which point the left LED
indicator turns solid red).
The following information details the
length of time that it will take for a
cold battery to warm up enough to
begin fast charging:
If the battery was being used
at -4º C (24.8º F), it will take
approximately 6 minutes for
the battery to warm up.
If the battery was being used
at -10º C (14.0º F), it will
take approximately 10
minutes for the battery to
warm up.
If the battery was being used
at -20º C (-4.0º F), it will take
approximately 22 minutes for
the battery to warm up.
If the battery was being used
at -30º C (-22.0º F), it will
take approximately 30
minutes for the battery to
warm up.
Abnormal condition: if this state
persists for more that two hours, the
battery cannot be charged in this
slot. See Troubleshooting Abnormal
Conditions.
Charger module is
malfunctioning: see
Troubleshooting Charger
Malfunction
Troubleshooting Abnormal Conditions
Check the battery contacts and the charger contacts for dirt or other obstructions that
might prevent the contacts from connecting properly. Clean the contacts, if necessary.
To clean the contacts, use a soft pencil eraser to clean metal connection points. You also
can use a three-row toothbrush style, general cleaning brush with natural hog hair bristles