Electrical Data
Supply voltage 24 (+10% / -15%)
V DC
Current consumption
approx. 0.7, max. 3 for t < 1 sec
A
Control Parameters
Setpoint w
for pressure adjusting range PA min….PA
max
w = 0/4 … 20
mA
Input load 25
Input configuration
E360 Electronics
E503 Electronics
Applied, related to GND
Isolated (500 kΩ)
Setpoint limitation
E360 Electronics
E503 Electronics
w > 35
w > 90
mA
mA
Adjustment ranges X0 and X1
See Chapter 6.2.1
Magnetic force switch-off at
(only with E503 electronics)
w < 3
mA
Voith Control Magnet (VRM)
marking with cable end
II 2G Ex db IIC T4
Protection IP 65 as per EN 60529
Ambient temperature TA at T4 -30 … +60 °C
… in connection with components
Cable entry
(cable end design)
II 2G Ex db IIC T4-T6