EasyManua.ls Logo

Voith DSG-B07112 - Page 5

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual
Voith Turbo
I/H Converter DSG-BXX112
I/H Converter DSG-BXX102
09 / 03 cet - Ochs/ZAN1 Voith Turbo GmbH & Co, KG Page: 5 / 21
3.626 - 018877 en D – 74564 Crailsheim
Type DSG- BXX 112
B03... B05... B07... B10... B30...
Output pressure
regulating range
P
A
[bar]
0..3 0..5 1..7 0..10 2..30
Input pressure
P
in
max [bar]
40 40 40 40 70
Flow rate line P ® A
Q1
[l/min]
at DP = 1 bar
18 18 18 17 21
Flow rate line A ® T
Q2
[l/min]
at DP = 1 bar
20 20 20 18 24
Regul. range approx.
P
A
max [bar]
at setpoint 20 mA
1..3 3..5 3,5..7 5..10 7..30
Regul. range approx.
P
A
min [bar]
at setpoint 4 mA
0..1
0..2
0..1,5
0..3
1..2
1,5..4
0..2
0..6
0..3
0..18
Type DSG- BXX 102
B05... B07...
Output pressure
regulating range
P
A
[bar]
0..5 1..7
Input pressure
P
in
max [bar]
40 40
Flow rate line P ® A
Q1
[l/min]
at DP = 1 bar
18 18
Flow rate line A ® T
Q2
[l/min]
at DP = 1 bar
20 20
Regul. range approx.
P
A
max [bar]
at setpoint 20 mA
3..5 3,5..7
Regul. range approx.
P
A
min [bar]
at setpoint 4 mA
0..1,5
0..3
1..2
1,5..4
The regulating range of P
A
min depends on the set pressure P
A
max.
The regulating range of P
A
min indicated in the first line refers to the minimum
adjustable pressure P
A
max.
Mechanical data:
Dimensions, fitting see chapter 10
Hydraulic connection see chapter 10
Mounting position see chapter 10
Sealing material FPM
Weight approx. 12 kg

Related product manuals