Using a volt meter, measure the voltage at your xtures by
removing the lamp and using the probes in the bulb receptacle.
Be sure that all other lamps are installed at the time of testing.
For integrated xtures, test voltage at the closest connection
point to the lighting xture. A good range is typically between
10.8 -15 volts for LED lighting xtures.
Quick Start Step 11
www.voltlighting.com
Go around and check that all of your xtures are on and
functioning properly. Flickering or xtures that aren’t powered
on could present a connection problem at the xture or lamp. If
a failed lamp is suspected, try replacing it with another that is
working in a different location. This will help you to troubleshoot
where the problem is.
Quick Start Step 10
HOLD
MIN MAX
RANGE
AUTO- V
LoZ
OFF
V
Hz
V
mV
A
COM
+
V
AC
12.00