3.2.4 ACA
AC Conversion Type:TRUE RMS responding, calibrated readings consistent
with sinusoidal waveform RMS. Frequency Range:50~60Hz.
3.2.5 Resistance Ω
Overload protection: effective value 220V
3.2.6 Capacitance
Overload protection: effective value 250V
warning:There is about 20pF dead zone in the 10nF,capacitance below 20pF can not be measured
3.2.7 Frequency
Overload protection: effective value 250V . Input sensitivity RMS: effective value 1V.
NOTE:If the voltage of the frequency being measured is above 30V,set the rotary function
switch to the ACV measured function and press “SELECT”key to enter voltage frequency
measured function,in order to avoid demage the instrument.
Range
40A
400A
600A
Resolution
10mA
100mA
1A
Accuracy
± (4.5%+25d)
± (4.5%+20d)
± (2.5%+15d)
Range
400 Ω
4k Ω
40k Ω
400k Ω
4M Ω
40M Ω
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1k Ω
10k Ω
Accuracy
± (1%+3d)
± (1.5%+5d)
Range
10nF
100nF
1uF
10uF
100uF
1000uF
10mF
Resolution
0.001nF
0.01nF
0.1nF
1nF
10nF
100nF
1uF
Accuracy
±(3%+20d)
±(3%+5d)
±(5%+5d)
Range
100Hz
1kHz
10kHz
100kHz
1MHz
10MHz
40MHz
Resolution
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
1kHz
10kHz
Accuracy
±(0.5%+3d)
3.